Specifying medical silicone hose for a respiratory device comes down to nine inputs: bore, wall, tolerance, hardness, temperature, pressure and vacuum duty, connector type, documentation and packaging. This OEM checklist explains each input, the questions to ask a supplier, and the mistakes that cost a revision.
Polyester braid, mesh braid and steel wire braid are three separate constructions, each with its own models, size range and burst data. This guide compares all three: ID 3–31.75 mm for polyester braid, ID 19–102 mm for mesh and wire, and how to choose.
Oxygen concentrators use medical grade tubing along the gas path, from the compressor and sieve beds to the flowmeter, humidifier and cannula. This guide maps each section, compares silicone, PVC and TPE, and shows when braided hose and which dimensions to specify.
Platinum and peroxide cured silicone tubing use different vulcanization chemistry. This guide compares by-products, odor, transparency and process control, explains what each means for medical and food-contact work, and shows what to send for a quotation.
ISO 10993 is the international standard family for biological evaluation of medical devices. This guide explains what cytotoxicity, skin sensitization and skin irritation reports cover, why oxygen concentrator tubing benefits from them, how ISO 10993 differs from USP Class VI, and how to request the reports with your order.
Our braided silicone hose carries one continuous rating: −40 °C to +200 °C (−40 to 392 °F). This guide separates continuous duty from the 250–300 °C peak of our separate high-temperature line, converts both temperature scales, and shows how to match the hose to the duty.
Steel wire braided silicone hose is a separate large-bore construction, not a variant of the polyester braid. This guide sets out its seven models from 19 to 102 mm, its own burst, wall and bend data, the vacuum duty it handles, and what to send for a custom quote.
Burst pressure in braided silicone hose is a minimum per model: ≥ 38 kg/cm² (3.73 MPa) at ID 3 mm, falling to ≥ 12 kg/cm² (1.18 MPa) at ID 31.75 mm. This guide explains why bore drives it, what full-vacuum capability means, and how to specify pressure and vacuum duty.
Mesh braided silicone hose is its own construction: a four-layer polyester woven reinforcement over a platinum-cured silicone bore, in seven models from ID 19 mm to ID 102 mm. Minimum burst is 5–15 kg/cm² (0.49–1.47 MPa), wall 4.5 mm, service −40 to +200 °C.
Polyester braided silicone hose has three layers: a platinum-cured silicone inner layer, a high-temperature polyester braid and a silicone jacket. It carries pressure, resists vacuum collapse and does not kink in bores from 3 mm to 31.75 mm at −40 to +200 °C. This guide covers construction and selection.
Braided silicone hose inside oxygen concentrators must carry pressure or resist vacuum collapse without kinking. Three constructions are published separately: polyester braid ID 3–31.75 mm, and mesh and steel wire braid ID 19–102 mm, each with its own burst and bend data. This guide covers construction and sourcing.
A custom medical silicone hose manufacturer runs an OEM project from specification to shipment. This guide walks through what a project needs, what you get back, lead times, samples and the questions procurement and quality teams ask before releasing a purchase order.